• Diesel Generator丨500GF丨SDEC
  • Diesel Generator丨500GF丨SDEC

Diesel Generator丨500GF丨SDEC

No.SDEC 12GTAA27-G33
SDEC series engine 450 - 500 kW @ 50Hz Tier 3 emissions
  • Diesel Generator丨500GF丨SDEC

Features

Heavy Duty Engine - Rugged 4-cycle industrial diesel delivers reliable power and fast response to load changes.

Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non-linear loads and fault clearing short-circuit capability.

Control system - The HGM6110Nelectronic control is standard equipment and provides total generator set system integration including automatic remote starting/stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto-shutdown at fault detection.

Cooling system - Standard cooling package provides reliable running at up to 50 °C (122 °F)

Low noise Enclosures - humanized design, the overall design of the chassis is compact and small, which has the role of reducing noise and protecting the generator set. 2MM steel box, rain proof, strong, surface resistance to ultraviolet light, rain, wear, not easy to fade and other advantages, bolts use rust, corrosion resistant stainless steel bolts; Reinforced mechanical door lock, long service life; Internal use of flame retardant muffler sponge, effectively reduce noise, more friendly to the environment. The interior is equipped with a top operating light for easy operation at night.

Fuel tank - Independent bottom for easy disassembly and maintenance. With wavy baffle, suitable for cutting. With lock refueling port, convenient refueling, anti-theft. Standard mechanical fuel gauge, can be customized electronic fuel gauge, you can check the oil level in the display. The use of oxidation resistance, high temperature resistance, high pressure special high pressure tubing, long service life. Anti-flatulence special fuel tank cap, safe to use.

Innovative Design & Prototype Testing - are key components of RAISE POWER's success in "increasing power by design." But it doesn't stop there. Fully committed to component testing, reliability testing, environmental testing, structural and life testing, as well as testing applicable to CSA, NEMA, EGSA and other standards, gives you confidence when choosing a SHRAISE generator set that these systems will deliver superior performance.

Warranty & Service - Backed by a comprehensive warranty and worldwide distributor and dealer network.

Generator Set Specifications
Standby
50 Hz
Prime
50 Hz
ModelkWkVAkWkVA
500GF50062545056312GTAA27-G33

Engine Specifications

Engine12GTAA27-G33
Prime Power505 kW
Engine Speed1500 rpm
Compression Ratio16:1
AspirationTurbocharged Air-cooling
Bore × Storke135 mm × 155 mm
Displacement26.6 L
No. of CylindersV-12
Speed ControlElectronic
Lubrication Capacity55-65 L
Coolant Capacity48 L

Alternator Specifications
Type Brushless, 4-pole, all-copper, single-point, rotating magnetic field
Stator2/3 pitch
Number of phases3-phase
Insulation systemClass H, compliant with NEMA MG1-1.65
Power factor1.0/0.8 hysteresis
Excitation methodAutomatic voltage regulation (AVR)
Connection method3-phase, 4-wire
Cooling methodFan-cooled
Telephone influence factor (TIF)<50°C, compliant with NEMA MG1-22.43
Telephone harmonic factor (THF)
<3%
 
  Alternator Brands Optional
 

Generator Set Options
Fuel Tank
Base Fuel Tank
□ External Independent Fuel Tank

Engine
Engine Air Filter:
    □ Standard
    Industrial
Shutdown - Low Oil Pressure Fault Shutdown
Extension Hose - Oil Drain
□ Engine Oil Heater

Alternator
AVR Self-Excitation
120°C Temperature Rise Generator
□ 105°C Temperature Rise Generator
□ Generator Heater, Single Phase
□ Single-Phase Output Generator

Control
□ AC Output Voltmeter/Amperemeter
Shutdown Switch - Emergency Stop
Auxiliary Output Relay
Auxiliary Signal Input and Relay Output
Electrical
1, 2, or 3 Circuit Breakers
□ 80% Load Protection Circuit Breaker
□ 80%/100% Load Overcurrent Protection Circuit Breaker
□ Battery Float Charger

Enclosure
□ T1 Class Low Noise Enclosure
T2 Low-Noise Cabinet
□ Rainproof Cabinet with Muffler

Cooling System
Shutdown - High Temperature, Low Coolant
 Warning - High Temperature, Low Coolant
Extension Hose - Coolant Drain
□ Coolant Heater Option:
    □ <4°C (40°F) - Cold Weather
    □ <-18°C (40°F) - Extreme Cold

Exhaust System
☑ Exhaust Connector
☑ Exhaust Muffler 

Towing System
□ Single-Axle or Double-Axle Trailer
□ Support Legs Mechanical/Hydraulic
□ Tires Tubeless/Solid Roll-On
□ Trailer Drawbar:
    □ Off-Road Drawbar - <40 km/h
    □ On-Road Drawbar - <80 km/h

Warranty Support
Basic Warranty - 2  year/3000 hours, primary 
□ Basic Warranty - 1 year/1500 hours, primary

□ 3-year spare warranty optional
□ 5-year spare warranty optional


Generator Set Accessories
□ Coolant heater
□ Battery heater kit
□ Engine oil heater
□ Remote control displays
□ Auxiliary output relays (2)
□ Auxiliary configurable signal inputs (8) and relay outputs (8)
□ Annunciator - RS485
□ Audible alarm
□ Remote monitoring device
□ Battery charger – stand-alone, 12V
□ Circuit breakers
□ Enclosure Sound Level 1 to Sound Level 2 upgrade kit
□ Base barrier - elevated generator set
□ Mufflers - industrial, residential or critical
□ Alternator PMG excitation
□ Alternator heater

Control System
Intelligent Control - An integrated generator set control system that provides voltage regulation, engine protection, and an operator interface.

Monitoring
- Provides battery monitoring and testing capabilities, as well as an intelligent starting control system.
RS485 - Network interface (standard) to devices such as remote annunciator for NFPA 110   applications.

Ambient operation - Suitable for operation in ambienet temperatures from -40°C to +70°C and altitudes to13,000 feet (5,000 meters).

Controller Brands Optional

    
Controller Function
Plain text multilingual LCD displaySimple user interface for easy operation
Mode ButtonAutomatic:Automatic start in case of mains failure
Manual:Start is controlled by the starter and the device remains on. Transfer to load if utility power fails
Stop:Start is controlled by the starter and the device remains on. If a utility fails, it will be transferred to the load
Prepare for operation/maintenance messagesStandard
Engine run time indicationStandard
Programmable start-up delay between 2-1500 secondsStandard (Distributor Programmable Only)
Mains voltage loss/restoration adjustableReal time
Future Set Ability Exerciser/Exercise Set Error WarningStandard
Operation/alarm/maintenance log50 events
Engine start sequenceLoop Start: 16 seconds on, 7 seconds off (maximum duration 90 seconds)
Starter LockThe starter does not re-engage until 5 seconds after the engine stops
Smart Battery ChargerStandard
Charger Failure / Missing AC WarningStandard
Low Battery/Battery Problem Protection and Battery Condition IndicationStandard
Automatic Voltage Regulation With Overvoltage and Undervoltage ProtectionStandard
Under frequency/Overload/Step Over current ProtectionStandard
Safety Fuse/Fuse Problem ProtectionStandard
Automatic Low Oil PressureStandard
Over crank/Over speed (@ 72 Hz)/pm Sense Loss ShutdownStandard
Engine High Temperature ShutdownStandard
Internal Fault/ Miswiring ProtectionStandard
Common External Fault CapabilityStandard
Field Upgradeable FirmwareStandard
Low Coolant Level ShutdownStandard

Generator Set Size

Open Type 
Length (mm)3600
Width (mm)1400
Height (mm)2000
Net Weight (kg)4450

This outline drawing is for reference only.See respective model data sheet forspecific model outline drawing number.Do not use for installation design.
Weights above are average. Actual weight varies with product configuration.

Download

Cooperation Application

We invite you to become our cooperative dealer. We will give you the most favorable purchase price and supporting services. If you are interested, please fill in the following information.
Company
Whatsapp / Mobile*
Email*
Content
Talk To An Expert
Company Name
Email*
Whatsapp / Mobile*
Which product(s) are you interested in?